CalculatorBoom

Convert Btu (IT)·feet per Hour per Sq. Foot per °F to Kilowatts per Meter per Kelvin

Btu (IT)·foot per Hour per Sq. Foot per °F (Btu·ft/(h·ft²·°F)) to Kilowatt per Meter per Kelvin (kW/(m·K)) thermal conductivity conversion — enter any value below to get an instant result, or use the table for common values.

Results from this calculator are estimates provided for general informational purposes only, based on formulas, rates, and standards commonly accepted as of 2026. Figures may differ slightly from other calculators or professional sources due to rounding methods, differing assumptions, or regional regulations, and rules may change over time. Always consult a qualified professional — such as a financial advisor, healthcare provider, or other relevant specialist — before making decisions based on these results.

The numeric value you want to convert. Decimals are accepted.

Result

1 Btu (IT)·foot per Hour per Sq. Foot per °F = 0.0017307 Kilowatts per Meter per Kelvin

1 Kilowatt per Meter per Kelvin = 577.80089 Btu (IT)·feet per Hour per Sq. Foot per °F

1 Btu·ft/(h·ft²·°F) in every supported unit

Conversion chart: Btu (IT)·foot per Hour per Sq. Foot per °F to Kilowatts per Meter per Kelvin

Conversion table

Btu (IT)·foot per Hour per Sq. Foot per °F (Btu·ft/(h·ft²·°F)) Kilowatt per Meter per Kelvin (kW/(m·K))
0.01 Btu·ft/(h·ft²·°F) 1.7307E-05 kW/(m·K)
0.1 Btu·ft/(h·ft²·°F) 0.00017307 kW/(m·K)
1 Btu·ft/(h·ft²·°F) 0.0017307 kW/(m·K)
2 Btu·ft/(h·ft²·°F) 0.0034614 kW/(m·K)
3 Btu·ft/(h·ft²·°F) 0.0051921 kW/(m·K)
5 Btu·ft/(h·ft²·°F) 0.0086535 kW/(m·K)
10 Btu·ft/(h·ft²·°F) 0.017307 kW/(m·K)
20 Btu·ft/(h·ft²·°F) 0.034614 kW/(m·K)
50 Btu·ft/(h·ft²·°F) 0.086535 kW/(m·K)
100 Btu·ft/(h·ft²·°F) 0.17307 kW/(m·K)
1000 Btu·ft/(h·ft²·°F) 1.7307 kW/(m·K)

Btu (IT)·foot per Hour per Sq. Foot per °F (Btu·ft/(h·ft²·°F))

Definition: The standard US customary thermal conductivity unit — Btu of heat energy conducted through a one-foot material thickness, per square foot of area, per hour, per degree Fahrenheit of temperature difference.

History: Built from the foot, hour, square foot, and Fahrenheit degree, all standard US construction measurements, giving American building engineers a conductivity unit matching everyday design calculations.

Current use: The standard "k-value" unit on US building material and insulation datasheets, forming the basis for the R-value ratings used throughout US residential and commercial construction.

Kilowatt per Meter per Kelvin (kW/(m·K))

Definition: A larger-scale conductivity unit for describing extremely good thermal conductors, where the base watt-per-meter-kelvin figure would otherwise run into the thousands.

History: A straightforward SI multiple of watt per meter per kelvin, applied to high-conductivity materials like pure metals where kilowatt-scale figures are more convenient.

Current use: Occasionally used in industrial heat-exchanger and power-electronics contexts involving highly conductive metal components.

Supported Units

Unit Symbol In W/(m·K)
Watt per Meter per Kelvin W/(m·K) 1 W/(m·K)
Watt per Centimeter per °C W/(cm·°C) 100 W/(m·K)
Kilowatt per Meter per Kelvin kW/(m·K) 1000 W/(m·K)
Calorie (IT) per Second per Centimeter per °C cal/(s·cm·°C) 418.68 W/(m·K)
Kilocalorie (IT) per Hour per Meter per °C kcal/(h·m·°C) 1.163 W/(m·K)
Btu (IT)·inch per Second per Sq. Foot per °F Btu·in/(s·ft²·°F) 519.22 W/(m·K)
Btu (IT)·foot per Hour per Sq. Foot per °F Btu·ft/(h·ft²·°F) 1.7307 W/(m·K)
Btu (IT)·inch per Hour per Sq. Foot per °F Btu·in/(h·ft²·°F) 0.1442 W/(m·K)

About These Parameters

Value
The thermal conductivity value you want to convert, expressed in the "From" unit. Accepts decimals.
From Unit
The unit your input value is currently measured in — the SI W/(m·K), or a US insulation datasheet's Btu·in/(h·ft²·°F) k-value.
To Unit
The conductivity unit you want the result converted into. Use the swap button to flip From and To instantly.

How Thermal Conductivity Conversion Works

The Formula

Every unit here is defined by a fixed multiplier relative to watts per meter per kelvin. To convert a value from one unit to another:

result = value × (factor of "From" unit ÷ factor of "To" unit)

For Btu (IT)·foot per Hour per Sq. Foot per °F → Kilowatt per Meter per Kelvin: multiply by 0.0017307. For example, 1 Btu·ft/(h·ft²·°F) × 0.0017307 = 0.0017307 kW/(m·K).

Conductivity (k) vs. Resistance (R)

Thermal conductivity (this page) is a property of the material itself, independent of how thick a piece of it you have. R-value, printed on US insulation packaging, is the inverse relationship scaled by an actual thickness — a thicker layer of the same material has a higher R-value even though its conductivity k hasn't changed. That's why doubling a wall's insulation thickness roughly doubles its R-value, but has no effect at all on the insulation material's underlying k-value in W/(m·K) or Btu·in/(h·ft²·°F).

Conductors vs. Insulators

Thermal conductivity spans an enormous range: solid copper conducts heat at roughly 400 W/(m·K), while modern aerogel insulation can be as low as 0.015 W/(m·K) — a difference of over 25,000 times. Materials engineers reach for this converter constantly when comparing candidate materials sourced from different countries' datasheets, since the same underlying physical property is reported in wildly different-looking numbers depending on the unit convention used.

Example

A material with a conductivity of 1 Btu·ft/(h·ft²·°F) equals 0.0017307 kW/(m·K). For scale, common fiberglass batt insulation sits around 0.04 W/(m·K), while structural concrete is roughly 1.7 W/(m·K) — over 40 times more conductive, which is why concrete alone provides negligible insulation value.

Frequently Asked Questions

How many Kilowatts per Meter per Kelvin are in 1 Btu (IT)·foot per Hour per Sq. Foot per °F?

1 Btu (IT)·foot per Hour per Sq. Foot per °F (Btu·ft/(h·ft²·°F)) equals exactly 0.0017307 Kilowatts per Meter per Kelvin (kW/(m·K)).

Why does US insulation use inches instead of feet for its k-value?

Most rigid foam and batt insulation products are only a few inches thick, so measuring conductivity per inch of thickness keeps the resulting numbers in a convenient, easy-to-compare range rather than the smaller decimals a per-foot figure would produce for the same material.

Does thermal conductivity change with temperature?

Yes, for most materials conductivity varies somewhat with temperature (and for some materials, quite significantly). The conversion factors on this page relate different UNITS for the same measured value; they don't account for how a material's own conductivity might shift between measurement conditions.

How accurate are these conversions?

Every conversion factor used here is the exact, internationally recognized relationship between the underlying energy, length, area, and temperature units — results are limited only by floating-point display precision, not by rounded conversion constants.

Convert Btu (IT)·foot per Hour per Sq. Foot per °F to Other Thermal Conductivity Units

Possible Thermal Conductivity Conversions

Calorie (IT) per Second per Centimeter per °C to Btu (IT)·inches per Hour per Sq. Foot per °F Watt per Centimeter per °C to Watts per Meter per Kelvin Btu (IT)·inch per Hour per Sq. Foot per °F to Kilocalories (IT) per Hour per Meter per °C Watt per Centimeter per °C to Kilocalories (IT) per Hour per Meter per °C Btu (IT)·foot per Hour per Sq. Foot per °F to Btu (IT)·inches per Second per Sq. Foot per °F Btu (IT)·inch per Second per Sq. Foot per °F to Btu (IT)·inches per Hour per Sq. Foot per °F Calorie (IT) per Second per Centimeter per °C to Watts per Meter per Kelvin Kilowatt per Meter per Kelvin to Kilocalories (IT) per Hour per Meter per °C Watt per Meter per Kelvin to Btu (IT)·inches per Second per Sq. Foot per °F Btu (IT)·inch per Second per Sq. Foot per °F to Kilowatts per Meter per Kelvin Btu (IT)·foot per Hour per Sq. Foot per °F to Kilocalories (IT) per Hour per Meter per °C Watt per Meter per Kelvin to Btu (IT)·inches per Hour per Sq. Foot per °F Btu (IT)·inch per Second per Sq. Foot per °F to Calories (IT) per Second per Centimeter per °C Btu (IT)·foot per Hour per Sq. Foot per °F to Watts per Meter per Kelvin Kilocalorie (IT) per Hour per Meter per °C to Btu (IT)·inches per Second per Sq. Foot per °F Btu (IT)·inch per Hour per Sq. Foot per °F to Btu (IT)·inches per Second per Sq. Foot per °F Btu (IT)·foot per Hour per Sq. Foot per °F to Watts per Centimeter per °C Watt per Meter per Kelvin to Watts per Centimeter per °C Btu (IT)·inch per Second per Sq. Foot per °F to Watts per Centimeter per °C Calorie (IT) per Second per Centimeter per °C to Watts per Centimeter per °C Watt per Centimeter per °C to Btu (IT)·inches per Second per Sq. Foot per °F Kilocalorie (IT) per Hour per Meter per °C to Watts per Meter per Kelvin Btu (IT)·foot per Hour per Sq. Foot per °F to Btu (IT)·inches per Hour per Sq. Foot per °F Btu (IT)·inch per Hour per Sq. Foot per °F to Kilowatts per Meter per Kelvin Kilowatt per Meter per Kelvin to Watts per Meter per Kelvin Kilowatt per Meter per Kelvin to Watts per Centimeter per °C Btu (IT)·inch per Hour per Sq. Foot per °F to Watts per Meter per Kelvin Calorie (IT) per Second per Centimeter per °C to Btu (IT)·feet per Hour per Sq. Foot per °F Kilowatt per Meter per Kelvin to Btu (IT)·inches per Second per Sq. Foot per °F Btu (IT)·inch per Hour per Sq. Foot per °F to Calories (IT) per Second per Centimeter per °C Watt per Meter per Kelvin to Kilocalories (IT) per Hour per Meter per °C Kilocalorie (IT) per Hour per Meter per °C to Calories (IT) per Second per Centimeter per °C Kilocalorie (IT) per Hour per Meter per °C to Btu (IT)·feet per Hour per Sq. Foot per °F Kilocalorie (IT) per Hour per Meter per °C to Kilowatts per Meter per Kelvin Btu (IT)·inch per Second per Sq. Foot per °F to Kilocalories (IT) per Hour per Meter per °C Watt per Centimeter per °C to Btu (IT)·inches per Hour per Sq. Foot per °F Watt per Meter per Kelvin to Kilowatts per Meter per Kelvin Calorie (IT) per Second per Centimeter per °C to Kilocalories (IT) per Hour per Meter per °C Kilocalorie (IT) per Hour per Meter per °C to Watts per Centimeter per °C Btu (IT)·foot per Hour per Sq. Foot per °F to Kilowatts per Meter per Kelvin Watt per Centimeter per °C to Btu (IT)·feet per Hour per Sq. Foot per °F Kilocalorie (IT) per Hour per Meter per °C to Btu (IT)·inches per Hour per Sq. Foot per °F Calorie (IT) per Second per Centimeter per °C to Btu (IT)·inches per Second per Sq. Foot per °F Kilowatt per Meter per Kelvin to Btu (IT)·feet per Hour per Sq. Foot per °F Btu (IT)·inch per Second per Sq. Foot per °F to Watts per Meter per Kelvin Btu (IT)·foot per Hour per Sq. Foot per °F to Calories (IT) per Second per Centimeter per °C Btu (IT)·inch per Hour per Sq. Foot per °F to Btu (IT)·feet per Hour per Sq. Foot per °F Btu (IT)·inch per Hour per Sq. Foot per °F to Watts per Centimeter per °C Watt per Centimeter per °C to Kilowatts per Meter per Kelvin Kilowatt per Meter per Kelvin to Btu (IT)·inches per Hour per Sq. Foot per °F Btu (IT)·inch per Second per Sq. Foot per °F to Btu (IT)·feet per Hour per Sq. Foot per °F Watt per Meter per Kelvin to Btu (IT)·feet per Hour per Sq. Foot per °F Watt per Meter per Kelvin to Calories (IT) per Second per Centimeter per °C Watt per Centimeter per °C to Calories (IT) per Second per Centimeter per °C Calorie (IT) per Second per Centimeter per °C to Kilowatts per Meter per Kelvin Kilowatt per Meter per Kelvin to Calories (IT) per Second per Centimeter per °C

See also